Most device control commands require a background session — run voltra connect <DEVICE_ID> first.
All device control commands require a persisted API key.
When not connected, some commands will auto-scan, connect, execute, and disconnect.
--percent selects the device's percentage-force interpretation and accepts integer values only. It automatically enables percentage force for that command; using an absolute chains or eccentric value switches that interpretation back to lbs. Do not combine --percent with --unit kg.
set-chain-mode writes the normal/inverse and Mountain switches together so the two directional curves cannot be enabled at the same time. All chain-mode changes require the device to be unloaded. Mountain is rejected when the connected device does not advertise support.
Phase 1: switch to isometric mode → zero-position check → load power on. Test results (peak force / RFD / TPF / impulse) are determined by the device and pushed via notifications. Cortex does not expose those realtime notifications through stream; after upload, completed historical results are available through workout list --workout-type 5 and workout sets <workout-id>.
voltra set-mode isometricvoltra check-cable-zerovoltra config accept-physical-riskvoltra load# … perform test; historical results are available through workout list/sets …voltra finish-training
Set device display unit preference. Must unload + finish-training first. Global, not per-mode. This does NOT convert input values — use --unit kg for input conversion.
voltra check-cable-zero
[--device-id <id>] [--device <id>] [--json]
Verify cable is at retracted zero position.
voltra cable-length <enter|exit>
[--device-id <id>] [--device <id>] [--json]
Enter/exit cable length adjustment mode.
voltra unloadvoltra finish-trainingvoltra set-weight-unit kgvoltra check-cable-zero --jsonvoltra cable-length enter